Manufacturer: Mitsubishi Electric
-
Product no : FR-D720-0.1K
-
Product type : FR-D700 Inverter
-
type : Easy and compact inverter FREQROL-D700 series three-phase 200V
-
Applicable motor capacity (kW) : 0.1kW
-
Output : Rated capacity (kVA) : 0.3
-
Rated current (A) : 0.8
-
Overload current rating : 150% 60s, 200% 0.5s (inverse time characteristics)
-
Voltage : 3-phase 200 ~ 240V
-
Regenerative braking torque : Maximum value and the acceptable usage : -
-
Power supply : Voltage class : Three-phase 200V class
-
Rated input AC voltage and frequency : 3-phase 200 ~ 240V 50Hz / 60Hz
-
AC voltage allowable variation : 170 ~ 264V 50Hz / 60Hz
-
Frequency permissible variation : ± 5%
-
Power supply capacity (kVA) : 0.4
-
Protective structure (JEM 1030) : Closed form (IP20), all closed structure series will be IP40.
-
Cooling system : Self-cooling
-
Approximate Mass (kg) : 0.5
-
Control specification : control method : Soft-PWM control / high carrier frequency PWM control (V / F control, general-purpose magnetic flux vector control, optimum excitation control can be selected)
-
Output frequency range : 0.2 ~ 400Hz
-
Frequency setting resolution : Analog input : 0.06Hz / 60Hz (terminal 2,4: 0 ~ 10V / 10bit), 0.12Hz / 60Hz (terminal 2,4: 0 ~ 5V / 9bit), 0.06Hz / 60Hz (terminal 4: 0 ~ 20mA / 10bit)
-
Digital input : 0.01Hz
-
Frequency accurac : Analog input : Within ± 1% of the maximum output frequency (25 °C ± 10 °C)
-
Digital input : Within 0.01% of the set output frequency
-
Voltage / frequency characteristic : Base frequency 0 ~ 400Hz any setting possible, constant torque reduction torque pattern can be selected
-
Starting torque : 150% more than if you set the slip correction in the (1Hz at the time) ... general-purpose magnetic flux vector control
-
Torque boost : Manual torque boost
-
Acceleration and deceleration time setting : 0.1 ~ 3600s (acceleration and deceleration individually configurable), straight or S-shaped acceleration and deceleration mode can be selected
-
DC braking : Operating frequency (0 to 120 Hz), operation time (0 to 10s), the operating voltage (0-30%) Variable
-
Stall prevention operation level : Operating current level can be set (0 to 200% variable), presence or absence can be selected
-
Torque limit level : None
-
Operation specification : Operational function : Upper and lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward and reverse rotation prevention, remote setting, the second function, multi-speed operation, regeneration avoidance, slip compensation, operation mode selection, offline auto-tuning function, PID control, computer link operation (RS-485), optimum excitation control, power failure stop, speed smoothing control, Modbus-RTU
-
Frequency setting signal Analog input terminal points : 2 points
-
Analog input terminal specifications : Terminal 2: 0 ~ 10V, 0 ~ 5V can be selected, terminal 4: 0 ~ 10V, 0 ~ 5V, 4 ~ 20mA can be selected
-
Digital input : Operation panel, input by the parameter unit, frequency setting unit selectable
-
Start signal : Forward and reverse individual, start signal self-holding input (3-wire input) can be selected
-
input signal Terminal points (contact input) : 5 points
-
Pulse-train input : None
-
Input terminal selection possible signal : Multi-speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, external thermal input, PU- external operation switch, V / F switching, output stop, start self-holding selection, positive rotation, reverse rotation command, inverter reset, PUNET change operation, external -NET change operation, command rights switching, inverter operation enable signal, PU operation Pr.178 ~ any signal from the external interlock Pr.182 (input terminal function selection) selected by the
-
Output signal : Output terminal (open collector output) Number : : 1 point
-
Output terminal (relay output) Number : 1 point
-
Output pin-selectable signal : During inverter operation, frequency arrival, overload alarm, output frequency detection, regenerative brake pre-alarm, electronic thermal pre-alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward reverse output, fan failure, FIN overheating pre-alarm, during a power failure deceleration, in PID control operation, in the PID output interruption, the safety monitor output, safety monitor output 2, during retry, life alarm, current average value monitor, remote output, minor fault output , abnormal output, abnormal output 3, Pr.190 any signal from the maintenance timer alarm, Pr.192, selected by the Pr.197 (output terminal function selection).
-
Output pin-selectable signal (when the option is installed) : Built-in options not be mounted
-
Output terminal points for display meter : 1 point
-
Output terminal specifications for display meter : FM: up to 2.4kHz
-
Pulse train output : None
-
For meter output pin-selectable signal : Output frequency, output current (steady), output voltage, frequency setting value, the converter output voltage, the regenerative brake duty, electronic thermal load factor, output current peak value, the converter output voltage peak value, reference voltage output, motor load factor, PID target value, PID measured value, output power, PID deviation, motor thermal load factor, inverter thermal load factor selected by Pr.54 FM terminal function selection, pulse train output (1440 pulses / s / full scale)
-
display: control panel Operating condition : Output frequency, output current (steady), output voltage, frequency setting value, cumulative energization time, actual operation time, the converter output voltage, the regenerative brake duty, electronic thermal load factor, output current peak value, the converter output voltage peak value, the motor load factor, PID target value, PID measured value, PID deviation, the inverter input and output terminal monitor, output power, integrated power, motor thermal load factor, inverter thermal load factor, it can be selected from the PTC thermistor resistance value
-
Abnormal contents : Display an abnormal content at the time of operation of the protection function, store the 8 doses abnormal contents (protective function just before the output voltage and current, frequency and cumulative energization time)
-
Protection and alarm function :
during acceleration over-current, constant speed during the over-current, over-current during deceleration, acceleration during overvoltage, constant speed during overvoltage, during deceleration overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheat, input phase failure, start-up time of the output side earth (ground) fault overcurrent, output phase failure, external thermal operation, PTC thermistor operation, parameter error, PU missing generation, the number of retries over, CPU abnormal, brake transistor abnormality, inrush resistance overheat, analog input error, stop by the stall prevention , output current detection value over, safety circuit abnormality
fan failure, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake pre-alarm, electronic thermal pre-alarm, maintenance output, undervoltage, operation panel lock, in the password setting, while the inverter is reset, safety stop in -
environment:Ambient temperature : -10 °C ~ + 50 °C (No freezing) (-10 °C ~ + 40 °C when the total closure structure specification)
-
Ambient humidity : Less than 90% RH (non-condensing)
-
Storage temperature : -20 °C ~ + 65 °C
-
atmosphere : Indoor (no corrosive gas, flammable gas, oil mist, dust and dirt)
-
Altitude, vibration : 1000m or less above sea level · 5.9m / s2 or less
-
Communication : RS-485, Modbus RTU
-
Shipping Weight : 3 Kg